@prefix skos: <http://www.w3.org/2004/02/skos/core#> .
@prefix ns0: <http://gcmd.gsfc.nasa.gov/kms#> .

<https://gcmd.earthdata.nasa.gov/kms/concept/9044c133-fbd1-440c-abd9-eccc8c0fa72c>
  skos:changeNote """2020-11-12 16:08:49.0 [sritz] Insert Concept 
add broader relation (CAFE [9044c133-fbd1-440c-abd9-eccc8c0fa72c,560765] - Chemical Meters/Analyzers [3d25724b-832f-4a61-b0b2-4f2ccecdba94,543779]); 
""", """2020-11-12 16:09:17.0 [sritz]  
insert AltLabel (id: null
category: primary
text: NASA Compact Airborne Formaldehyde Experiment
language code: en); 
""", """2020-11-12 16:10:50.0 [sritz]  
insert Definition (id: null
text: NASA Compact Airborne Formaldehyde Experiment (CAFE) is a nonresonant laser-induced fluorescence instrument for airborne in situ measurement of formaldehyde (HCHO). The instrument is described here with highlighted improvements from the predecessor instrument, COmpact Formaldehyde FluorescencE Experiment (COFFEE). CAFE uses a 480 mW, 80 kHz laser at 355 nm to excite HCHO and detects the resulting fluorescence in the 420–550 nm range. The fluorescence is acquired at 5 ns resolution for 500 ns and the unique time profile of the HCHO fluorescence provides measurement selectivity. CAFE achieves a 1σ precision of 160 pptv (1 s) and 90 pptv (10 s) for [HCHO] = 0 pptv. The accuracy of CAFE, using its curve-fitting data processing, is estimated as ±20 % of [HCHO] + 100 pptv. CAFE has successfully flown on multiple aircraft platforms and is particularly well-suited to high-altitude research aircraft or small air quality research aircraft where high sensitivity is required but operator interaction and instrument payload is limited.
language code: en); 
""" ;
  ns0:altLabel [ ] ;
  skos:definition "NASA Compact Airborne Formaldehyde Experiment (CAFE) is a nonresonant laser-induced fluorescence instrument for airborne in situ measurement of formaldehyde (HCHO). The instrument is described here with highlighted improvements from the predecessor instrument, COmpact Formaldehyde FluorescencE Experiment (COFFEE). CAFE uses a 480 mW, 80 kHz laser at 355 nm to excite HCHO and detects the resulting fluorescence in the 420–550 nm range. The fluorescence is acquired at 5 ns resolution for 500 ns and the unique time profile of the HCHO fluorescence provides measurement selectivity. CAFE achieves a 1σ precision of 160 pptv (1 s) and 90 pptv (10 s) for [HCHO] = 0 pptv. The accuracy of CAFE, using its curve-fitting data processing, is estimated as ±20 % of [HCHO] + 100 pptv. CAFE has successfully flown on multiple aircraft platforms and is particularly well-suited to high-altitude research aircraft or small air quality research aircraft where high sensitivity is required but operator interaction and instrument payload is limited."@en ;
  skos:prefLabel "CAFE"@en ;
  skos:inScheme <https://gcmd.earthdata.nasa.gov/kms/concepts/concept_scheme/instruments> ;
  skos:broader <https://gcmd.earthdata.nasa.gov/kms/concept/3d25724b-832f-4a61-b0b2-4f2ccecdba94> ;
  a skos:Concept .

<https://gcmd.earthdata.nasa.gov/kms/concept/3d25724b-832f-4a61-b0b2-4f2ccecdba94>
  skos:prefLabel "Chemical Meters/Analyzers"@en ;
  a skos:Concept ;
  skos:narrower <https://gcmd.earthdata.nasa.gov/kms/concept/9044c133-fbd1-440c-abd9-eccc8c0fa72c> .

